Questions???
Call 253-853-7462

       

This page is part of our previous web site,
to visit our new web site and extensive on line catalogue,
click here!

 

OVERALL DIMENSIONS

TLO-l-E 
49 1/2" W X 117" H X 73" D
(126cm) (297cm) (185cm)
TLO-I-G
 
49 1/2" W X 117" H X 73" D
(126cm) (297cm) (185cm)
TLO-II-E
 
60 1/2" W X 117" H X 82 1/2" D
(154cm) (262cm) (209.5cm)
TLO-II-G
 
60 1/2" W X 117" H X 82 1/2" D
(154cm) (297cm) (209.5cm)

OVEN INTERIOR DIMENSIONS

TLO-I-E 
37" W X 75" H X 39" D
(94cm) (190cm) (99cm)
TLO-I-G
 
37" W X 75" H X 39" D
(94 cm) (190 cm) (99 cm)
TLO-II-E
 
48" W X 75" H X 52" D
(122cm) (190cm) (132cm)
TLO-II-G
 
48" W X 75" H X 52" D
(122cm) (190cm) (132cm)

SHIPPING WEIGHT
TLO-I-E 2 600 lbs 
(1 180 kg) approx.
TLO-I-G 2 600 lbs 
(1 180 kg) approx.
TLO-II-E 3 600 lbs 
(1 635 kg) approx.
TLO-ll-G 3 600 lbs 
(1 635 kg) approx.

ELECTRICAL SYSTEM

TLO-I-E 3 phases:
120/208V-122 A -44 kW -4 Wires -60 cycles
120/240V -104 A -44 kW -4 Wires -60 cycles
220/380V -74 A -49 kW -4 Wires -50 cycles
600V - 43 A -44 kW - 3 Wires - 60 cycles

TLO-II-E 3 phases:|
480V -75 A - 62 kW - 3 Wires - 60 cycles
600V - 60 A -62 kW -3 Wires - 60 cycles

ELECTRICAL SYSTEM

TLO-l-G 3 phases:
120/208V -8 A -3 kW -4 Wires -60 cycles
120/240V -8 A -3 kW -4 Wires -60 cycles
220/380V -4 A -2,7 kW -4 Wires -50 cycles
Gas: BTUH
Natural: 167 000 Propane: 167 000

TLO-II-G 3 phases:
120/208V-10 A -3,5 kW -4 Wires - 60 cycles
120/240V - 10 A -3,5 kW -4 Wires - 60 cycles
Gas: BTUH
Natural: 225 000 Propane: 225 000

Specifications and design subject to change without notice.

 

A. GAS : 3/4" inlet
B. Electrical Inlet
C. WATER :Cold water pipe
D. Drain: 1/2"
E. OVEN HOOD VENT: 6"
F. EXHAUST: 6" diameter gas flue
exhaust with draft hood

INSTALLATION
- Unit must be on level floor. Not approved for installation on combustible floor surfaces;
- Certified for zero clearance to combustible surfaces sides and back;
- Installation of this product conforms to local codes.
Use National Electric code ANSI/NFPA 70-1990 or latest edition
and National Fuel Gas code ANSI/NFPA Z223.1 -1992 or latest edition.
In Canada, use Natural Gas installation code CAN/CGA B149.1;
- No drain required.
- Nine foot minimum ceiling

 

RACK SPECIFICATIONS

 

 

 

 

Bakery Equipment.com, Inc.
PH: 253-853-7462 M-F 8am-4pm PST
FX: 253-853-7487

All Contents Copyright © 2000 - 2002 BAKERY EQUIPMENT.COM INC. All rights reserved. Reproduction in whole or in part in any form or medium without express written permission of BAKERY EQUIPMENT.COM INC. is prohibited.