Casasanta 4 Door Front Load Or Pass Thru Industrial Proofer, Model CAPTPR 4DR-7CDR.
Your Price: | $0.00 * USD |
Item Number: | 27280 |
Manufacturer: | Casasanta |
Model No.: | CAPTPR 4DR-7CDR |
*Price Does NOT include cost of crating, shipping, delivery or installation.
Model: CAPTPR 4DR-7CDR.
Front Load Or Pass Thru
4 Doors.
Rack Depth Capacity: 7 Double Racks.
Total Rack Capacity: 28 Double Racks.
Rack Type: 15 Level Stainless Steel Accommodating 18" x 26" Peel Boards.
Convection Specification: Recirculating System C/W Side Wall Ducting.
O.A. Dims: 301.13"L x 201.17"W x 160"H
PROOFING SYSTEM INTERIOR/EXTERIOR FINISH:
Stainless steel heavy gauge exterior/interior finish complete
Includes all walls, roof, support channels, trim, flashing, caps
Wall Thickness - 3" / Roof Thickness 4" / Door Construction 3"
SS Interior and Exterior Fastners.
Interlocking wall and roof panels complete with moisture resistant,
memory retaining, high temperature gasket.
Heavy gauge Stainless Steel Exterior and Interior Panels with Guarding.
Heavy gauge Integrated Door Handle with Self Closing Latches.
Heavy Duty Die Cast Door Hingers.
Door Gaskets, Door Sweeps and Sealed Viewing Glass.
Internal Structure Protection Complete with HDPE.
ELECTRIC STEAM/HEAT GENERATING SYSTEM:
Heavy Guage Stainless Steel Electric Driven Steam and Heat Generating System.
Industrial High Quality Heating Elements, Heavy Duty re-circulating blower System.
High efficiency steam generating system for accurate and rapid recovery of heat and humidity.
RoofTop Climate Coniditioning System complete with Water Supplied Steam Generator.
CONTROL SYSTEM TOUCH SCREEN:
Controlling System: PLC Electrical System c/w Touch Screen
Digital temperature and humidity controls complete with dual display for accurate adjustment of heat and percent relative humidity.
Humidity and Temperature sensor for precise control of steam generating system.
Main power On/Off.
MAIN CONTROL PANEL:
460 VAC, 3 phase, FLA to be Determined.
Touch safe electrical system for safe, trouble free operation and maintenance.
Re-settable, short-circuit protection devices on all electrical components for safe operation.
ESA, CSA Electrical Approval / Professionally Finished Wire Installation.